INVERSOR UNDAE SINGULARIS DKWD-PURE CUM REGULATORE MPPT INCLUSO
Parametrum
Modellum DKWD | 70112/24 | 10212/24 | 15224/48 (152) | 20224/48 (202) | 30224/48 (302) | |
Potentia Aestimata | 700W | 1000W | 1500W | 2000W | 3000W | |
Potentia Maxima (20ms) | 2100VA | 3000VA | 4500VA | 6000VA | 9000VA | |
Motor Incipiens | 0.5HP | 1HP | 1.5HP | 2HP | 3HP | |
Tensio Batteriae | 12/24VDC | 12/24VDC | 24/48VDC | 24/48VDC | 24/48VDC | |
Maxima AC onerationis fluxus | 0A~20A (Pro exemplo, maxima potentia onerandi est quarta pars potentiae aestimatae) | |||||
Cursus onerandi moderatoris solaris incorporatus (ad libitum) | 10A~60A (PWM vel MPPT) | 24/48V (PWM: 10A~60A/MPPT: 10A~100A) | ||||
Magnitudo (L*A*A) | 340x165x283 | 410x200x350 | ||||
Magnitudo sarcinae (L*W*Hmm) | 405x230x340 (1 frustum) / 475x415x350 (2 frustum) | 475x265x410 | ||||
NW (kg) | 9.5 (1 pz) | 10.5 (1 pz) | 11.5 (1 pz) | 17 | 20.5 | |
GW (kg) | 11 (1 pz) | 12 (1 frusta) | 13 (1 pz) | 19 | 22.5 | |
Methodus Installationis | Turris | |||||
Modellum DKWD | 80248/96/192 | 10348/96/192 | 12396/192 | 153192 | 203192 | |
Potentia Aestimata | Octo kW | Decem chiliophagi | 12 kW | 15KW | 20 kW | |
Potentia Maxima (20ms) | 24KVA | 30KVA | 36KVA | 45KVA | 60KVA | |
Motor Incipiens | 5HP | 7HP | 7HP | Decem HP | 12HP | |
Tensio Batteriae | 48/96/192VDC | 48/96V/192VDC | 96/192VDC | 192VDC | 192VDC | |
Maxima AC onerationis fluxus | 0A~40A (Pro exemplo), Maximum | 0A~20A (Pro exemplo, maxima potentia onerandi est quarta pars potentiae aestimatae) | ||||
Cursus onerandi moderatoris solaris incorporatus (ad libitum) | Modulatio Pulsus (PWM): (48V: 120A; 96V: 50A/100A; 192V/384V: 50A); Moderator Pulsus (MPPT): (48V: 100A/200A; 96V: 50A/100A; 192V/384V: 50A). | 50A/100A | ||||
Magnitudo (L*A*A) | 540x350x695 | 593x370x820 | ||||
Magnitudo sarcinae (L*W*Hmm) | 600*410*810 | 656*420*937 | ||||
NW (kg) | 66 | 70 | 77 | 110 | 116 | |
GW (kg) | 77 | 81 | 88 | 124 | 130 | |
Methodus Installationis | Turris | |||||
Inputum | Ambitus Tensionis Ingressae DC | 10.5-15VDC (tensio singularis pilae) | ||||
Ambitus Tensionis Ingressae AC | 73VAC~138VAC (110VAC) / 83VAC~148VAC (120VAC) / 145VAC~275VAC (220VAC) / 155VAC~285VAC (230VAC) / 165VAC~295VAC (240VAC) (700W~7000W) | |||||
Frequentiae Ingressus AC | 45Hz~55Hz(50Hz)/ 55Hz~65Hz(60Hz) | |||||
Modus onerandi AC | Tria gradus (constans fluxus, constans tensio, fluctuans onus) | |||||
Exitus | Efficacia (Modus Accumulatoris) | ≥85% | ||||
Tensio Egressus (Modus Accumulatoris) | 110VCA ± 2% / 120VCA ± 2% / 220VCA ± 2% / 230VCA ± 2% / 240VCA ± 2% | |||||
Frequentia Emissionis (Modus Accumulatoris) | 50Hz±0.5 vel 60Hz±0.5 | |||||
Unda Egressus (Modus Batteriae) | Unda Sinusoidali Pura | |||||
Efficacia (Modus AC) | >99% | |||||
Tensio Egressus (Modus AC) | Inscriptionem sequere | |||||
Frequentia Egressus (Modus AC) | Investigatio Automataria | |||||
Distortio formae undae exitus (Modus Accumulatoris) | ≤3% (Onus lineare) | |||||
Nulla iactura oneris (Modus Accumulatoris) | ≤1% potentiae aestimatae | |||||
Nulla iactura oneris (Modus AC) | ≤2% potentiae aestimatae (cargator in modo AC non operatur) | |||||
Nulla iactura oneris (Modus energiae conservandae) | ≤10W | |||||
Typus Batteriae | Accumulator VRLA | Tensio Impletionis: 14.2V; Tensio Fluctuationis: 13.8V (tensio singularis pilae) | ||||
Adapta pilam | Parametri onerationis et exonerationis variorum generum accumulatorum secundum requisita usoris aptari possunt. | |||||
Protectio | Monitum deminutionis tensionis pilae | Praedefinitum officinae: 11V (tensio singularis pilae) | ||||
Protectio a deminutione tensionis acumulatoris | Praedefinitum officinae: 10.5V (tensio singularis pilae) | |||||
Monitum de nimia tensione pilae | Praedefinitum officinae: 15V (tensio singularis pilae) | |||||
Praesidium contra supertensionem altilium | Praedefinitum officinae: 17V (tensio singularis pilae) | |||||
Tensio recuperationis tensionis excessivae pilae | Praedefinitum officinae: 14.5V (tensio singularis pilae) | |||||
Protectio potentiae nimiae | Protectio automatica (modus altilium), interruptor automaticus vel assecuratio (modus AC) | |||||
Protectio contra circuitum brevem exitus inversoris | Protectio automatica (modus altilium), interruptor automaticus vel assecuratio (modus AC) | |||||
Protectio temperaturae | >90°C (Exitus clauditur) | |||||
Alarma | A | Status operandi normalis, tinnitus nullum sonum alarmis habet. | ||||
B | Tibicen quater per secundum sonat cum pila deficiat, tensio abnormalis sit, vel praesidium contra onerationem excessivam. | |||||
C | Cum machina primum accenditur, tinnitus quinque sonabit cum machina normaliter fungitur. | |||||
Intra moderatorem solarem | Modus Implendi | PWM vel MPPT | ||||
PV Tensio Ingressa | PWM: 15V-44V (systema 12V); 30V-44V (systema 24V); 60V-88V (systema 48V); 120V-176V (systema 96V); 240V-352V (systema 192V); 300V-400V (systema 240V); 480V-704V (systema 384V). | |||||
Maxima Tensio Ingressa PV (Voc) | PWM: 50V (systema 12V/24V); 100V (systema 48V); 200V (systema 96V); 400V (systema 192V); 500V (systema 240V); 750V (systema 384V). | |||||
Potentia Maxima Programmatis Photovoltaici (PV) | Systema 12V: 140W (10A)/280W (20A)/420W (30A)/560W (40A)/700W (50A)/840W (60A)/1120W (80A)/1400W (100A); | |||||
Damnum subsidii | ≤3W | |||||
Maxima efficientia conversionis | >95% | |||||
Modus Operandi | Primum Accumulatore/Primum AC/Modus Energiae Conservandae | |||||
Tempus Translationis | ≤4ms | |||||
Ostendere | LCD | |||||
Methodus thermalis | Ventilator refrigerans in potestate intellegenti | |||||
Communicatio (Optionalis) | RS485/APP (monitoratio WIFI vel monitoratio GPRS) | |||||
Ambitus | Temperatura operandi | -10℃~40℃ | ||||
Temperatura repositionis | -15℃~60℃ | |||||
Strepitus | ≤55dB | |||||
Altitudo | 2000m (Plus quam deminutio) | |||||
Humiditas | 0%~95%, nulla condensatio |
Modellum DKWD | 35248/96 (352) | 40248/96(402) | 50248/96(502) | 60248/96(602) | 70248/96/192(702) | |
Potentia Aestimata | 3500W | 4000W | 5000W | 6000W | 7000W | |
Potentia Maxima (20ms) | 10500VA | 12000VA | 15000VA | 18000VA | 21000VA | |
Motor Incipiens | 3HP | 3HP | 4HP | 4HP | 5HP | |
Tensio Batteriae | 48/96VDC | 48/96VDC | 48/96VDC | 48/96VDC | 48/96/192VDC | |
Maxima AC onerationis fluxus | 0A~20A (Pro exemplo, maxima potentia onerandi est quarta pars potentiae aestimatae) | |||||
Cursus onerandi moderatoris solaris incorporatus (ad libitum) | 24/48V (PWM: 10A~60A/MPPT: 10A~100A) | 48V (PWM: 10A~120A/MPPT: 10A~100A) / | ||||
Magnitudo (L*A*A) | 410x200x350 | 491x260x490 | ||||
Magnitudo sarcinae (L*W*Hmm) | 475x265x410 | 545x315x550 | ||||
NW (kg) | 21.5 | 29 | 30 | 31.5 | 36 | |
GW (kg) | 23.5 | 32 | 33 | 34.5 | 39 | |
Methodus Installationis | Turris | |||||
Modellum DKWD | 253240 | 303240 | 403384 | |||
Potentia Aestimata | 25kW | 30 kW | 40 kW | |||
Potentia Maxima (20ms) | 75KVA | 90KVA | 120KVA | |||
Motor Incipiens | 15HP | 15HP | 20HP | |||
Tensio Batteriae | 240VDC | 240VDC | 384VDC | |||
Maxima AC onerationis fluxus | 0A~20A (Pro exemplo, maxima potentia onerandi est quarta pars potentiae aestimatae) | |||||
Cursus onerandi moderatoris solaris incorporatus (ad libitum) | 50A/100A | 50A/100A | ||||
Magnitudo (L*A*A) | 593x370x820 | 721x400x1002 | ||||
Magnitudo sarcinae (L*W*Hmm) | 656*420*937 | 775x465x1120 | ||||
NW (kg) | 123 | CLXVII | 192 | |||
GW (kg) | 137 | 190 | 215 | |||
Methodus Installationis | Turris | |||||
Inputum | Ambitus Tensionis Ingressae DC | 10.5-15VDC (tensio singularis pilae) | ||||
Ambitus Tensionis Ingressae AC | 73VAC~138VAC (110VAC) / 83VAC~148VAC (120VAC) / 145VAC~275VAC (220VAC) / 155VAC~285VAC (230VAC) / 165VAC~295VAC (240VAC) (700W~7000W) | |||||
Frequentiae Ingressus AC | 45Hz~55Hz(50Hz)/ 55Hz~65Hz(60Hz) | |||||
Modus onerandi AC | Tria gradus (constans fluxus, constans tensio, fluctuans onus) | |||||
Exitus | Efficacia (Modus Accumulatoris) | ≥85% | ||||
Tensio Egressus (Modus Accumulatoris) | 110VCA ± 2% / 120VCA ± 2% / 220VCA ± 2% / 230VCA ± 2% / 240VCA ± 2% | |||||
Frequentia Emissionis (Modus Accumulatoris) | 50Hz±0.5 vel 60Hz±0.5 | |||||
Unda Egressus (Modus Batteriae) | Unda Sinusoidali Pura | |||||
Efficacia (Modus AC) | >99% | |||||
Tensio Egressus (Modus AC) | Inscriptionem sequere | |||||
Frequentia Egressus (Modus AC) | Investigatio Automataria | |||||
Distortio formae undae exitus (Modus Accumulatoris) | ≤3% (Onus lineare) | |||||
Nulla iactura oneris (Modus Accumulatoris) | ≤1% potentiae aestimatae | |||||
Nulla iactura oneris (Modus AC) | ≤2% potentiae aestimatae (cargator in modo AC non operatur) | |||||
Nulla iactura oneris (Modus energiae conservandae) | ≤10W | |||||
Typus Batteriae | Accumulator VRLA | Tensio Impletionis: 14.2V; Tensio Fluctuationis: 13.8V (tensio singularis pilae) | ||||
Adapta pilam | Parametri onerationis et exonerationis variorum generum accumulatorum secundum requisita usoris aptari possunt. | |||||
Protectio | Monitum deminutionis tensionis pilae | Praedefinitum officinae: 11V (tensio singularis pilae) | ||||
Protectio a deminutione tensionis acumulatoris | Praedefinitum officinae: 10.5V (tensio singularis pilae) | |||||
Monitum de nimia tensione pilae | Praedefinitum officinae: 15V (tensio singularis pilae) | |||||
Praesidium contra supertensionem altilium | Praedefinitum officinae: 17V (tensio singularis pilae) | |||||
Tensio recuperationis tensionis excessivae pilae | Praedefinitum officinae: 14.5V (tensio singularis pilae) | |||||
Protectio potentiae nimiae | Protectio automatica (modus altilium), interruptor automaticus vel assecuratio (modus AC) | |||||
Protectio contra circuitum brevem exitus inversoris | Protectio automatica (modus altilium), interruptor automaticus vel assecuratio (modus AC) | |||||
Protectio temperaturae | >90°C (Exitus clauditur) | |||||
Alarma | A | Status operandi normalis, tinnitus nullum sonum alarmis habet. | ||||
B | Tibicen quater per secundum sonat cum pila deficiat, tensio abnormalis sit, vel praesidium contra onerationem excessivam. | |||||
C | Cum machina primum accenditur, tinnitus quinque sonabit cum machina normaliter fungitur. | |||||
Intra moderatorem solarem | Modus Implendi | PWM vel MPPT | ||||
PV Tensio Ingressa | PWM: 15V-44V (systema 12V); 30V-44V (systema 24V); 60V-88V (systema 48V); 120V-176V (systema 96V); 240V-352V (systema 192V); 300V-400V (systema 240V); 480V-704V (systema 384V). | |||||
Maxima Tensio Ingressa PV (Voc) | PWM: 50V (systema 12V/24V); 100V (systema 48V); 200V (systema 96V); 400V (systema 192V); 500V (systema 240V); 750V (systema 384V). | |||||
Potentia Maxima Programmatis Photovoltaici (PV) | Systema 12V: 140W (10A)/280W (20A)/420W (30A)/560W (40A)/700W (50A)/840W (60A)/1120W (80A)/1400W (100A); | |||||
Damnum subsidii | ≤3W | |||||
Maxima efficientia conversionis | >95% | |||||
Modus Operandi | Primum Accumulatore/Primum AC/Modus Energiae Conservandae | |||||
Tempus Translationis | ≤4ms | |||||
Ostendere | LCD | |||||
Methodus thermalis | Ventilator refrigerans in potestate intellegenti | |||||
Communicatio (Optionalis) | RS485/APP (monitoratio WIFI vel monitoratio GPRS) | |||||
Ambitus | Temperatura operandi | -10℃~40℃ | ||||
Temperatura repositionis | -15℃~60℃ | |||||
Strepitus | ≤55dB | |||||
Altitudo | 2000m (Plus quam deminutio) | |||||
Humiditas | 0%~95%, nulla condensatio |















Quod officium offerimus?
1. Officium designandi.
Tantum nobis indica functiones quas desideras, ut puta potentiam electricam, applicationes quas onerare vis, quot horas systema operari debes, et cetera. Systema energiae solaris rationabile tibi designabimus.
Diagramma systematis et configurationem accuratam faciemus.
2. Officia licitationis
Hospites in parandis documentis licitationis et datis technicis adiuvare.
3. Servitium disciplinae
Si novus es in negotio accumulationis energiae et disciplina eges, ad nostram societatem venire potes ut discas, aut technicos mittimus ut te adiuvent in arte tua exercenda.
4. Munus installationis et munus sustentationis
Praebemus etiam officia montandi et sustentationis pretio opportuno et accessibili.

5. Auxilium mercatorium
Magnum auxilium clientibus qui nostram notam "Dking power" praedicant, praestamus.
Ingeniarios et artifices mittimus ut te adiuvent, si opus sit.
Certas partes extras quorundam productorum gratis ut substitutiones mittimus.
Quod est minimum et maximum systema energiae solaris quod producere potes?
Minima vis solaris systema quod produximus est circiter 30W, qualis est lumina solaris viae. Sed plerumque minima vis ad usum domesticum est 100W, 200W, 300W, 500W, et cetera.
Plerique homines 1kw 2kw 3kw 5kw 10kw etc. ad usum domesticum malunt; plerumque AC 110v vel 220v et 230v est.
Systema energiae solaris maximum quod produximus est 30MW/50MWH.


Quomodo est tua qualitas?
Qualitas nostra est summa, quia materiis optimae qualitatis utimur et probationes rigorosas materiarum facimus. Et systema QC severissimum habemus.

Accipitisne productionem personalizatam?
Ita. Dic nobis modo quid velis. Investigationem et progressionem (R&D) ad usum aptavimus et acumulatores lithinos ad energiam conservandam, acumulatores lithinos temperaturae humilis, acumulatores lithinos ad vehicula motrice, acumulatores lithinos ad vehicula extra viam publicam, systemata energiae solaris, et cetera producemus.
Quod est tempus praesentationis?
Solite XX-XXX dies
Quomodo tua producta spondes?
Per tempus warantiae, si causa producti est, tibi productum substituendum mittemus. De quibusdam productis tibi novum cum proxima missione mittemus. Producta diversa cum variis condicionibus warantiae. Sed antequam mittamus, imaginem vel video requirimus ut certi simus problema producti nostri esse.
officinae











Casus
400KWH (192V2000AH Lifepo4 et systema accumulationis energiae solaris in Philippinis)

Systema accumulationis energiae solaris et batteriae lithii 200KW PV+384V1200AH (500KWH) in Nigeria

Systema accumulationis energiae solaris et cum accumulatore lithio 400KW PV+384V2500AH (1000KWH) in America.



Certificationes